Event ID: 78
Task Category: None
Level: Error
Keywords: Classic
User: N/A
Computer:
Description:
Activation context generation failed for "C:\Program Files (x86)\TeraByte Drive Image Backup and Restore Suite\imagew.exe".Error in manifest or policy file "" on line . A component version required by the application conflicts with another component version already active. Conflicting components are:. Component 1: C:\WINDOWS\WinSxS\manifests\x86_microsoft.windows.common-controls_6595b64144ccf1df_6.0.19041.4355_none_a865f0c28672571c.manifest. Component 2: C:\WINDOWS\WinSxS\manifests\amd64_microsoft.windows.common-controls_6595b64144ccf1df_6.0.19041.4355_none_60b8b9eb71f62e16.manifest.
Event ID 78 SideBySide error on upgrade from 4.03 to 4.04
-
- Posts: 171
- Joined: Mon Apr 17, 2023 4:08 am
-
- Posts: 3891
- Joined: Thu May 05, 2011 10:37 pm
Re: Event ID 78 SideBySide error on upgrade from 4.03 to 4.04
I don't see that running the x86 version on x64 windows 10, run the x64 version instead. The manifest was changed to use processorArchitecture="*" which is supposed to be the correct option for any platform.
-
- Posts: 171
- Joined: Mon Apr 17, 2023 4:08 am
Re: Event ID 78 SideBySide error on upgrade from 4.03 to 4.04
I see only the x86 and amd64 versions of microsoft.windows.common-controls on this Windows 10 22H2 fully-patched system.
I mounted 2 different 4.03 images, and there was no x64 version.
I mounted 2 different 4.03 images, and there was no x64 version.
-
- Posts: 3891
- Joined: Thu May 05, 2011 10:37 pm
Re: Event ID 78 SideBySide error on upgrade from 4.03 to 4.04
The issue was identified, it only comes up if you run imagew (x86) version on x64 windows. If you run imagew64 on x64 windows it won't be an issue nor if you run imagew on x86 windows.
If it's an issue for anyone, you can download the installer again (updated) and reinstall.
If it's an issue for anyone, you can download the installer again (updated) and reinstall.